Acoustics & Measurement
Reverberation Time in Recording Studios: What RT60 Actually Tells You
In this article
Technical contribution from On-Site Acoustic Testing (OSAT USA). Editorial disclosure: OSAT USA and The Audio Magazine are under common ownership.
Reverberation time is one of the most familiar measures in room acoustics, yet it is easy to misuse in a small recording studio. A single RT60 figure may conceal a room that is very dry at high frequencies but rings at particular bass frequencies. The objective is not simply to make every room as dead as possible; it is to understand how sound decays in the intended working environment.
What RT60 represents
RT60 describes the time associated with a 60 dB decay of sound level after the excitation ceases, conventionally evaluated from a decay curve under defined measurement conditions. A full 60 dB decay is often not measurable above background noise. Instead, standardized methods may estimate the equivalent decay time by fitting a shorter portion of the curve.
| Descriptor | Typical decay range used | Interpretation |
|---|---|---|
| EDT | 0 to −10 dB | Early decay time, extrapolated to 60 dB; sensitive to the initial decay. |
| T20 | −5 to −25 dB | Decay slope extrapolated to 60 dB. |
| T30 | −5 to −35 dB | Longer decay interval requiring sufficient signal-to-noise ratio. |
ISO 3382 is a family of standards for measuring room acoustic parameters in different room types. Select the applicable procedure and measurement objective rather than treating any software readout labeled RT60 as a standards-compliant measurement.
Frequency matters
Room materials absorb differently across the spectrum. A room filled with thin foam can have a short high-frequency decay but retain considerable low-frequency energy. Averaging the entire spectrum into one figure removes important information. Evaluate octave or third-octave bands where appropriate and examine low-frequency decay individually.
Consider an illustrative room with estimated T20 values of 0.30 s at 1 kHz, 0.28 s at 2 kHz and 0.75 s at 125 Hz. The upper bands appear controlled, but the low-frequency decay deserves investigation. These hypothetical numbers are not measured results or universal acceptance criteria.
Our worked acoustic measurement examples include a band-by-band T20 extrapolation table.
Small-room limitations
Conventional reverberation-time interpretation assumes conditions in which decay is sufficiently representative of the room. At low frequencies in a small room, discrete modes and location-dependent behavior may dominate rather than a statistically diffuse sound field. A decay estimate taken at one position can therefore describe a local response, not the entire room.
Use frequency-versus-time waterfalls, spectrograms and multiple measurement positions to examine this behavior. See TAM’s room modes and standing waves guide. Modal decay may be more useful than a single reverberation value for deciding where to place bass trapping or adjust monitor position.
A practical measurement workflow
- Define whether you are characterizing a control room, live room, vocal booth or other space. Record furnishing and treatment conditions.
- Use a suitable measurement microphone, known signal routing and a reproducible excitation such as a swept sine with appropriate impulse-response processing.
- Capture measurements at multiple source and receiver positions where the objective warrants it. A single monitor-to-listener response is useful for that monitoring path but may not characterize the room as a whole.
- Check that the usable decay is above background noise and that the selected analysis interval is appropriate. Do not interpret a curve that has already reached the noise floor as continuing acoustic decay.
- Compare decay by frequency band and examine early reflections, response and low-frequency behavior together. Save the raw measurements so later changes can be compared under equivalent conditions.
For a practical software workflow, see TAM’s Room EQ Wizard guide. A home measurement can be valuable for tuning a studio, while formal compliance requires the applicable method and documented instrumentation and conditions.
How much reverberation is appropriate?
A vocal booth should not necessarily have the same decay as a live tracking room, nor should a control room be designed solely around one RT number. Room size, purpose, speaker layout, early reflection control, frequency response and decay uniformity all contribute to suitability. A studio used to record drums may deliberately retain a different acoustic character from a space used for voiceovers.
Do not confuse decay with sound isolation
Reverberation measures behavior within a space. Sound isolation concerns transmission between spaces. Increasing internal absorption can change the reverberant level without fixing an unintended sound path through a door or structure. Both may matter in a studio, but they require different objectives and measurements.
For an overview of professional room-acoustic and sound-isolation methods, see OSAT’s building acoustics reference.
For a complete measurement-led treatment workflow, see Recording Studio Acoustic Treatment: A Practical Guide.