Skip to content
What's New?
Browse Acoustics & Measurement →

Acoustics & Measurement

Three Worked Acoustic Measurement Examples for Recording Studios

By On-Site Acoustic Testing (OSAT USA) ·

In this article
  1. Example 1 — The door in a high-performance wall
  2. Example 2 — Isolate a contribution from the measured background
  3. Example 3 — Decay time is not a single number for the room
  4. Document your own diagnostic measurements

Technical contribution from On-Site Acoustic Testing (OSAT USA). Editorial disclosure: OSAT USA and The Audio Magazine are under common ownership.

Acoustic measurements become much more useful when you understand the calculations behind the reported numbers. These three worked examples demonstrate how a weak door affects a composite partition, how background noise affects a mechanical noise measurement, and how a shorter measured decay interval can be extrapolated to an equivalent reverberation time.

Data note: All numerical data on this page are synthetic, calculated teaching examples. They are not OSAT project results, design guarantees or substitutes for the applicable standardized test procedures.

Example 1 — The door in a high-performance wall

Assume a 20 m² separation consists of an 18 m² wall with a transmission loss of 60 dB and a 2 m² door. At one frequency, the composite transmission coefficient is the area-weighted sum of the individual coefficients. Transmission loss is −10 log₁₀ of that coefficient.

For a 30 dB door:

τ = (18 × 10⁻⁶ + 2 × 10⁻³) / 20 = 0.0001009

TL = −10 log₁₀(τ) ≈ 40.0 dB

Calculated composite transmission loss at one frequency
Door TL (dB) Wall TL (dB) Composite TL (dB)
25 60 35.0
30 60 40.0
35 60 44.9
40 60 49.6
45 60 53.9
50 60 57.2

Notice that improving the door from 30 to 40 dB increases the calculated composite loss by approximately 9.6 dB. Improving an already strong wall while retaining the original door would yield little benefit in this simplified example. This is not a composite STC calculation: the calculation must be performed using frequency-specific data before any appropriate classification is derived. It excludes indirect transmission and assumes idealized area-weighted transmission. Read the installed door isolation guide and the studio sound isolation guide.

Try other wall and door combinations with the interactive composite transmission loss calculator.

Example 2 — Isolate a contribution from the measured background

Suppose a room has two stable, sufficiently independent noise contributions. Compare the total with a representative background measurement made under otherwise equivalent conditions, after an authorized operating-state change. Under those assumptions, energetic subtraction estimates the contribution of the changed source:

Lsource = 10 log₁₀(10^(Ltotal/10) − 10^(Lbackground/10))

Illustrative octave-band data, dB re 20 µPa
Band (Hz) Total Background Difference Estimated contribution
63 45 38 7 44.0
125 39 31 8 38.3
250 32 27 5 30.3
500 28 25 3 Limited; see note
1000 24 23 1 Limited; see note

At 63 Hz the estimated contribution is 44.0 dB, not 7 dB. At 500 Hz, the 3 dB separation makes the result highly sensitive to variations and measurement uncertainty. At 1 kHz the 1 dB separation is too small for a confident attribution here. A specific standardized test may prescribe different correction limits and reporting rules; use those instead of this teaching example when conducting formal measurements.

Only compare equivalent measurement metrics and durations. Do not subtract a peak from an Leq or compare different weightings. Never disable required ventilation or other safety systems to obtain a lower background. See HVAC noise diagnosis and sound level measurement terminology.

Use the background noise subtraction calculator to explore the effect of changing the total-to-background difference.

Example 3 — Decay time is not a single number for the room

Imagine that a linear fit to a decay curve between −5 dB and −25 dB gives a 20 dB decay interval of 0.25 seconds at 125 Hz. Extrapolating that slope to 60 dB yields T20 = 0.75 seconds. Repeat the calculation for other bands:

Hypothetical fitted decay slopes
Band (Hz) 20 dB fitted interval (s) Extrapolated T20 (s)
125 0.25 0.75
250 0.18 0.54
500 0.14 0.42
1000 0.10 0.30
2000 0.09 0.27

The shorter decay in the upper bands does not resolve the longer decay at 125 Hz. A small room may exhibit individual modal resonances and nonuniform decay; inspect the impulse response, multiple positions and frequency-dependent time behavior. A fitted slope does not become a standards-compliant result merely because it has been extrapolated. Read the reverberation time guide for the distinctions between T20, T30 and EDT.

Document your own diagnostic measurements

Use the printable Studio Acoustic Measurement Worksheet to document frequency-band levels, background conditions, instrument checks and diagnostic observations.

Use TAM’s existing printable room measurement log to record microphone locations, operating conditions and treatment changes. Print it directly or use your browser’s Save as PDF option. The Audio & Studio Calculators collection contains complementary tools for distance, wavelength and room modes.

Keep the original data and clearly separate measured results, calculated estimates, possible diagnoses and contractual acceptance decisions. For formal testing requirements, see the acoustic report review checklist. These examples are intended to improve interpretation and repeatability, not to certify an installation.

For a complete measurement-led treatment workflow, see Recording Studio Acoustic Treatment: A Practical Guide.

More to read

Scroll to Top