Measuring Sound Levels in the Studio: dBA, dBC, dBZ, Leq and Peak

By On-Site Acoustic Testing (OSAT USA) ·

In this article
  1. Acoustic decibels are not digital decibels
  2. Frequency weighting: A, C and Z
  3. Fast, Slow, Leq and peak are different measurements
  4. Choosing metrics for the actual question
  5. Calibration and instrument limitations
  6. Make measurements repeatable

Technical contribution from On-Site Acoustic Testing (OSAT USA). Editorial disclosure: OSAT USA and The Audio Magazine are under common ownership.

Two meters can be exposed to the same sound and report different numbers without either being defective. Before interpreting an acoustic measurement, establish what is being measured, how the signal is weighted and how long the measurement lasts. A reading of “85 dB” without that information is incomplete.

Acoustic decibels are not digital decibels

Airborne sound pressure level uses a reference pressure of 20 micropascals. A digital audio meter normally reports level relative to full scale (dBFS). Unless a recording chain has been acoustically calibrated, a DAW cannot tell you the actual SPL in the room. Likewise, a loudspeaker’s electrical input level is not an acoustic measurement.

Frequency weighting: A, C and Z

Weighting What it does Typical use
A Strongly attenuates low frequencies and modifies other parts of the spectrum. Many occupational exposure and environmental noise measurements.
C Retains considerably more bass than A-weighting. Supplementary assessment of bass-heavy sound; C-weighted peak where specified.
Z Nominally flat frequency weighting over the instrument’s specified range. Broadband measurements and spectral investigations where appropriate.

A large difference between C- and A-weighted levels can suggest substantial low-frequency content, but does not identify the frequency, source or transmission path. Examine octave-band or narrowband spectra to investigate further. For room background noise, see our Noise Criteria guide.

Fast, Slow, Leq and peak are different measurements

Fast and Slow time weightings use exponential averaging, with nominal time constants of 125 milliseconds and one second respectively. A maximum Fast-weighted reading is the greatest Fast-weighted level during an interval, not the true instantaneous peak. A peak sound level measures the largest weighted pressure magnitude during the interval.

Equivalent continuous sound level, Leq,T, represents the constant sound level with the same mean-square pressure over the stated duration. LAeq,15min therefore describes an A-weighted energy average over 15 minutes, not the arithmetic average of the decibel readings. Two equal-duration periods at 60 and 70 dB produce approximately 67.4 dB when combined energetically, not 65 dB. The higher level contributes disproportionately to the total.

Choosing metrics for the actual question

Question Useful measurements
Is the ventilation system too loud for recording? Octave-band levels, LAeq,T and appropriate room noise criterion with normal HVAC operation.
How loud is the monitoring session? Time-averaged level at the listening position, with documented programme and duration.
What is causing an intermittent noise? Time history, event levels, frequency spectra and operating-state records.
Is there a bass-heavy disturbance? Frequency-band levels and supplementary C- or Z-weighted measurements.

Exposure assessments require the applicable occupational or other exposure procedure, not simply a momentary SPL reading. See TAM’s hearing protection article.

Calibration and instrument limitations

IEC 61672 specifies performance requirements for sound level meters. IEC 60942 addresses sound calibrators. For formal work, use instrumentation meeting the applicable requirements, with appropriate periodic verification and field checks before and after measurements. A field check at one frequency does not prove the accuracy of every frequency band. Microphone response, instrument self-noise, overload, orientation, reflections, wind and changing source conditions can all affect results.

Phone applications and recording interfaces are useful for relative comparisons when conditions are controlled. Their absolute readings should not be represented as compliant measurement results without establishing suitability of the entire system. In particularly quiet rooms, the microphone and instrument noise floor can determine the reading instead of the room.

For comparable energy-based measurements, use the background noise subtraction calculator. It is not appropriate for subtracting peak levels.

Make measurements repeatable

Our printable acoustic measurement worksheet provides fields for instrument checks, metrics, weighting, duration and frequency-band measurements.

Record the microphone position, equipment operating state, weighting, metric, duration, instrument and calibration information. Save the original data rather than only a screenshot. When comparing changes, keep test conditions equivalent. The best measurement is the one that answers the question being asked and can be interpreted later.

For professional acoustic measurement methods, consult OSAT’s field measurement capabilities. For audio signal units, see TAM’s decibel reference.