Studio Acoustic Measurement Worksheet

All studio forms

Prepared by On-Site Acoustic Testing (OSAT USA) for The Audio Magazine. Use this worksheet to document diagnostic acoustic measurements in a studio or control room. Print this page or select Save as PDF in your browser’s print dialog. Complete one copy per measurement location and operating configuration.

Scope: This is a general-purpose documentation aid, not a standardized test form, certification or substitute for a project-specific measurement procedure. OSAT USA and The Audio Magazine are under common ownership.

1. Project and measurement objective

Studio / project  
Room / receiver position  
Date and time / operator  
Objective / applicable criterion (if any)  
Source room / source position  
Operating conditions / doors / HVAC  
Instrument / microphone / serial numbers  
Calibration reference / field check before and after  
Metric, weighting, duration and analysis bandwidth  
Raw data filename / photo reference  

2. Frequency-band results

Use only the columns relevant to the objective. Enter sound levels in dB re 20 µPa and decay estimates in seconds; identify the exact metrics and analysis interval above. Use equivalent source and receiver metrics for a level difference. Do not treat that difference as transmission loss or a formal STC/ASTC rating. Background subtraction and decay estimates require adequate measurement conditions. Mark unavailable or limited results rather than inventing values.

Octave band (Hz) Source level (dB) Receiver / total (dB) Background (dB) Level difference (dB) Decay estimate (s)
63          
125          
250          
500          
1000          
2000          
4000          
8000          

For formal ratings, record the frequency resolution and other information required by the adopted standard separately. The octave-band table above is not sufficient for deriving a formal STC or ASTC rating.

3. Observations, limitations and next steps

Dominant frequency bands / events  
Suspected source or transmission path (hypothesis)  
Measurement limitations / background interference  
Corrective work proposed or completed  
Retest configuration / date  
Acceptance criterion and decision (only if applicable)  

4. Before filing the measurement

  • Confirm the measurement objective, units, weighting and duration.
  • Record the operating configuration, positions and equipment used.
  • Retain raw measurement data and any field calibration records.
  • Identify background-limited or otherwise invalid measurements.
  • Keep measured data separate from calculated estimates and diagnostic hypotheses.
  • Compare only equivalent measurements when evaluating changes.

Related technical references

See three worked acoustic measurement examples for calculation methods, sound level measurement terminology for metrics and the acoustic test report checklist for formal acceptance questions. The existing Room Measurement Log is better suited to logging multiple REW sweeps or monitor placement experiments. Browse all studio forms.