Software Tutorials
Decibels Explained: dB, dBu, dBV, dBFS and dB SPL in Audio
In this article
Audio engineers use the decibel to describe everything from a microphone signal to a digital peak meter and the sound pressure in a control room. Those measurements are not interchangeable. The letters after dB identify the reference, and knowing the reference is essential when setting levels, comparing equipment or interpreting a specification.
dB, dBu, dBV, dBFS and dB SPL at a glance
| Unit | Reference | Typical use |
|---|---|---|
| dB | A ratio; reference depends on context | Gain, attenuation, level difference |
| dBu | 0.775 V RMS | Professional analog audio voltage |
| dBV | 1 V RMS | Analog audio voltage |
| dBFS | Digital full scale, with the meter convention stated | Digital recording and playback levels |
| dB SPL | 20 micropascals RMS in air | Acoustic sound pressure level |
What does a decibel measure?
A decibel expresses a logarithmic ratio. For power, the difference is 10 log10(P2/P1). For voltage or sound pressure, the difference is 20 log10(A2/A1), where the same reference and appropriate measurement conditions apply. Doubling voltage gives approximately +6.02 dB; doubling power gives +3.01 dB. Doubling voltage into the same resistance quadruples power. None of these relationships means that perceived loudness necessarily doubles.
dBu and dBV: analog signal levels
For a measured RMS voltage V, dBu = 20 log10(V/0.775) and dBV = 20 log10(V/1). The inverse relationships are V = 0.775 × 10^(dBu/20) and V = 10^(dBV/20). In these expressions V is in volts RMS.
| Reference level | RMS voltage |
|---|---|
| −10 dBV | 0.316 V |
| 0 dBu | 0.775 V |
| 0 dBV | 1.000 V |
| +4 dBu | 1.228 V |
| +22 dBu | 9.756 V |
The common nominal professional level of +4 dBu is about 11.8 dB above −10 dBV. Both are nominal operating conventions, not necessarily the maximum clean output of a particular device. dBu is a voltage reference independent of load impedance; it is not the same unit as dBm, which references one milliwatt of power.
dBFS: the digital reference
In conventional fixed-point PCM, 0 dBFS denotes the full-scale digital limit. Peak readings for signals below that limit are negative. RMS meter conventions differ, so compare like with like. Floating-point processing can represent levels above nominal full scale internally, but fixed-point exports and physical converters still have finite limits.
There is no universal conversion from dBFS to dBu. If an interface is calibrated so that a −18 dBFS sine wave produces +4 dBu, then a full-scale sine wave would correspond to +22 dBu, assuming linear operation and the same metering convention. Other converters may have different calibration. Consult the device documentation and verify the level with suitable instrumentation.
dB SPL: acoustic sound pressure
Sound pressure level is 20 log10(p/20 µPa), where p is RMS sound pressure in air. A pressure of 1 Pa corresponds to approximately 94 dB SPL. The reading depends on the acoustic field, position, frequency weighting and measurement method. A digital peak meter or an uncalibrated browser microphone cannot automatically provide absolute sound pressure level.
When comparing measurements, note whether they are A-weighted, C-weighted or Z-weighted, and whether the number describes an equivalent continuous level, a maximum time-weighted level or a peak. These are different quantities.
How this applies to recording and mixing
Set analog preamp and outboard levels according to their nominal operating levels and headroom, and check the digital converter separately. Avoid assuming a particular dBFS reading means the same analog voltage on every interface. When calibrating monitors, use a repeatable test signal and suitable acoustic measurement equipment at a safe level.
Explore TAM’s gain staging guide, printable gain staging worksheet and studio monitor calibration guide. For acoustic propagation estimates, see the SPL versus distance calculator. The audio calculator collection contains additional engineering tools.